Handled Liquid
SKM Type pumps are suitable for clean or slightly contaminated liquids with low viscosity
Technical Data
Discharge Flange | DN 32__DN 250 mm |
---|---|
Capacity | up to 1000 m3/h |
Head | up to 550 m |
Speed | up to 2950 rpm |
Operating Temperature | -10o C up to 110o C (140 C*) |
Casing Pressure (Pmax) | 30 bar (63 bar)* |
( Pmax : Suction Pressure + Shut off Head) | |
( * ) The material of pump differ according to the type of pumped liquid, operating temperature and pressure. Contact our company for detailed information. |
- In standard production. Suction flange is placed on the right side and close to the coupling while discharge flange is at the other end radially upwards. The position of the suction and discharge flanges can be turned in 90o increments if requested during order.
- Axial thrust is minimized by rear wear ring/balance hole.
- All impellers are balanced statically and dynamically according to ISO 1940 class 6.3.
- Horizontal, ring section, multistage, centrifugal pumps with closed impellers and diffusers.
- 10 models from DN 32 to DN 250
- Suction nozzle flanges are according to TS EN 1092-2 / PN 16 and discharge nozzle flanges are according to TS EN 1092-2 / PN 40 (PN 63)
- Soft packing is applied in standard production up to 110o C. Between 110o C and 140o C, soft packing sealing may also be applied together with the stuffing box cooling
- Pumps with mechanical seal can also be manufactured upon request.
Design Features
- Horizontal, ring section, multistage, centrifugal pumps with closed impellers and diffusers.
- 10 models from DN 32 to DN 250
- Suction nozzle flanges are according to TS EN 1092-2 / PN 16 and discharge nozzle flanges are according to TS EN 1092-2 / PN 40 (PN 63)
Shaft Sealing
- Soft packing is applied in standard production up to 110o C. Between 110o C and 140o C, soft packing sealing may also be applied together with the stuffing box cooling
- Pumps with mechanical seal can also be manufactured upon request.
Pump Designation
Pump Type | -SKM |
---|---|
Heavy-duty Design | -K |
Discharge Nozzle (DN-mm) | 100 |
Number of Stage | / 6 |