TK-3C TK-5C Multi Jet Dry Type Water Meters

General

  • Multijet principle assures a long service time
  • Low head loss
  • MID Certificated
  • Good sensivity in intial starting
  • Available for optical reading
  • Body internally/externally e/p powder painted
  • Electrostatic painted body made of corrosion resistance brass
  • Special glass with high resistance to pressure and impact
  • Non-return valve
  • Vacuum mechanism (TK-5)
  • 360 rotating lid
  • Suitable for cold water up to 50 C
  • 3 years warranty
  • Almost no maintenance
  • Service and spare parts available for 10 years

Performance Data

75/33/EC TK-3C TK-5C
Nominal Flow Qn (m3/h) 3.5 10
Maximum Flow Qmax (m3/h) 7.0 20
Transitional Flow Qt (m3/h) 0.0525 0.15
Minimum Flow Qmin (m3/h) 0.035 0.10
   
Permanent Flow Q3 (m3/h) 6.3 16
Overload Flowrate Q4 (m3/h) 7.875 20
Transitional Flowrate Q2 (m3/h) 0.063 0.16
Minimum Flowrate Q1 (m3/h) 0.039 0.10
Initial Flowrate Qi (I/h) 7 15
Maximum Working Pressure (bar) 16 16
Maximum Working Temperature (°C) 50 50
Metrological Class (75/33/EC) C C
Q3/Q1 (MI-001 OIML R49) 160 160
Pressure Loss (Q3) 0.6 0.6
Maximum Registration Capacity 99999 99999
Smallest Reading Capacity 0.00005 0.00005
Mounting on the Network Horizontal Horizontal
Unit Weight 2.20 4.50
Package Weight (without connections) (kg) 23.50 19.00
Package Weight (with connections) (kg) 28.00 24.00
Quantity per package 10 4
Package Dimensions (cm) 26X51.5X29 30X32X34

Dimensions

  TK-3C TK-5C  
Nominal diameter 25 40 mm
Connecting diameter G 1 1/4 G 2  
Total overall meter hight     H 120 150 mm
Axis Height       h 40.5 46 mm
Lenght              L 360 300 mm
Width               B 97 132 mm
Length with connections LB 375 435 mm
TOP